Huawei's OptiXsense ES100 is a laser detector module designed for gas leak detection in manholes. Integrated into the partner's main unit and installed inside the manhole, this module provides 24/7 online detection and rapid reporting of gas leak alarms, ensuring urban gas safety.

1. Accurate measurement, with an accuracy of 40% or higher.
Based on a highly stable TDLAS chip and a high-tolerance optical design
Repeatability deviation rate: Huawei: ±3% VS Industry average: ±5%
2. Durable and water resistant
With its anti-condensation air chamber design, it is not afraid of being submerged in water.
Huawei: Supports repeated water immersion VS Industry: Easily damaged by water immersion
3. Low power consumption, no need to replace battery for 3 years
Temperature control fine-tuning algorithm reduces power
Huawei: Batteries last 3 years on a single charge VS Industry experts: Batteries last 1-2 years on a single charge
4. All-weather, unaffected by extreme cold or heat.
The device meets the high reliability test level of thousands of hours.
Huawei: -40℃~70℃ VS Industry standard: -30℃~70℃
Technical Specifications
| parameter | Huawei OptiXsense ES100 |
| Product Dimensions | Sensor: φ44mm*86mm(h) |
| Thread: φM20mm*15mm | |
| weight | 150g |
| Measuring gas | methane |
| Detection principle | TDLAS |
| Measurement range | 0~20%VOL |
| Error Specification | ±3%LEL @0~5%VOL (Absolute error, at room temperature) ±5%FS @5~20%VOL (Relative error, at room temperature) |
| Repeatability | ≤3% |
| T90 response time | ≤15s |
| Operating temperature | -40℃~70℃ |
| Operating humidity | 0~100%RH (non-condensing) |
| Working air pressure | 86~106kPa |
| Operating voltage | 3.0~3.6V |
| Power consumption | ≤120mW (Typical power consumption at room temperature 25℃) Note: Typical power consumption calculated based on a single 15s working time at room temperature 25℃. |
| Output method | Standard TTL (3.3V) serial communication, baud rate: 9600bps |
| Explosion-proof rating | Ex ib IIC T4 Gb |
| Protection level | IP68 |