CloudEngine 6800 Series Data Center Switches

CloudEngine 6800 Series Data Center Switches

Details

The new generation of high-performance, high-density intelligent 10/25/50GE Ethernet access switches provides 40/100/200GE uplink ports.

70a7417a-2462-467b-81de-922c73c1cdb5


1. High reliability


M-LAG ultra-fast failover, millisecond-level switching in case of link failure.

2. Intelligent Operation and Maintenance


Actively detect all network paths and monitor network health status in real time.

3. Open


Interoperable and open SDN switch wins gold award at Interop Japan.



Technical parameters


1. CE6855 Technical Parameters

modelCE6855-48XS8CQCE6855-48T8CQ
port48 x 10GE+8 x 40/100GE48 x 10GE Base-T + 8 x 40/100GE
Switching capacity4.8Tbps/96Tbps4.8Tbps/96Tbps
Packet forwarding rate2000Mpps2000Mpps
reliabilityLACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
MoFRR
LACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
MoFRR
DPCF
O&MTelemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Telemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event
Data center characteristics

1588v2
MACsec
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
VXLAN Mapping

1588v2
MACsec
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
Power consumption138W227W
Power supply model600 W AC&240 V DC
1200 W DC
1200W AC&240V DC
1200W DC
Power supply methodAC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
AC:90V to 290V;HVDC: 190V~290V
DC:-38.4V DC~-72V DC;+40V DC~+57V DC



2. CE6820 Technical Parameters

modelCE6820-48S6CQ-ACE6820H-48S6CQ
port48 x 10GE+6 x 40/100GE48 x 10GE+6 x 100GE
Switching capacity2.56Tbps/40.96Tbps2.56Tbps/40.96Tbps
Packet forwarding rate1080Mpps1080Mpps
cache21MB21MB
reliabilityLACP
Hardware BFD (minimum packet interval 3.3ms)
LACP
Hardware BFD (minimum packet interval 3.3ms)
O&MTelemetry
ERSPAN Enhancement
Telemetry
Netstream
ERSPAN Enhancement
Data center characteristicsM-LAG
ECN
M-LAG
Power consumption282W282W
Power supply model600W AC&240V DC
1000W DC
1200W HVDC
600W AC
1000W DC
1200W DC
Power supply methodAC:90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~400V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~400V
380V HVDC: 190V~400V


3. CE6857 Technical Parameters


modelCE6857E-48S6CQCE6857F-48S6CQCE6857F-48T6CQ
port48 x 10GE+6 x 40/100GE48 x 10GE+6 x 40/100GE48x10GE Base-T+6 x 40/100GE
Switching capacity4.8Tbps/96Tbps4.8Tbps/96Tbps4.8Tbps/96Tbps
Packet forwarding rate2000Mpps2000Mpps2000Mpps
cache32MB32MB32MB
reliabilityLACP
Differential segment
LACP
Differential segment
Hardware BFD (minimum packet interval 3.3ms)
LACP
Differential segment
Hardware BFD (minimum packet interval 3.3ms)
O&MTelemetry
Netstream
sFlow
Telemetry
Netstream
sFlow
ERSPAN Enhancement
Telemetry
Netstream
sFlow
ERSPAN Enhancement
Data center characteristicsVXLAN routing 和 bridging
BGP-EVPN
M-LAG
DCBX、PFC、ETS
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
DCBX、PFC、ETS
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
DCBX、PFC、ETS
Power consumption148W148W148W
Power supply model600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
Power supply methodAC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400



4. CE6870 Technical Parameters

modelCE6870-48S6CQ-EI-A
port48 x 10GE+6 x 40/100GE
Switching capacity2.16Tbps/19.44Tbps
Packet forwarding rate900Mpps
cache8GB
reliabilityLACP
Supports BFD for BGP/IS-IS/OSPF/Static Routing/VXLAN
O&MTelemetry
Netstream
sFlow
ERSPAN
Data center characteristicsVXLAN routing 和 bridging
BGP-EVPN
M-LAG
DCBX、PFC、ETS
Power consumption194 W
Power supply model600W AC&240V DC
1000W -48V DC
1200W HVDC
Power supply methodAC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V


5. CE6881 Technical Parameters


modelCE6881-48S6CQCE6881-48T6CQCE6881H-48S6CQCE6881H-48T6CQ
port48 x 10GE+6 x 40/100GE48 x 10 GE Base-T+6 x 40/100GE48 x 10GE+6 x 40/100GE48 x 10 GE Base-T+6 x 40/100GE
Switching capacity4.8Tbps/96Tbps4.8Tbps/96Tbps4.8Tbps/96Tbps4.8Tbps/96Tbps
Packet forwarding rate2000Mpps2000Mpps2000Mpps2000Mpps
reliabilityLACP
Differential segment
Hardware BFD (minimum packet interval 3.3ms)
LACP
Differential segment
Hardware BFD (minimum packet interval 3.3ms)
LACP
Hardware BFD (minimum packet interval 3.3ms)
LACP
Hardware BFD (minimum packet interval 3.3ms)
O&MTelemetry
Netstream
sFlow
ERSPAN Enhancement
Telemetry
Netstream
sFlow
ERSPAN Enhancement
Telemetry
Netstream
ERSPAN Enhancement
Telemetry
Netstream
ERSPAN Enhancement
Data center characteristicsVXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC、ECN
VXLAN Mapping
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC、ECN
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PTP
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PTP
Power consumption194W347W194 W347W
Power supply model600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
Power supply methodAC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V



6. CE6885 Technical Parameters

modelCE6885-48YS8CQCE6885H-48YS8CQCE6885L-48YS8CQCE6885-LL-56F
port48 x 10/25GE/50GE+8 x 40/100GE/200GE48 x 25GE/50GE+8 x 100GE/200GE48 x 25GE+8 x 40/100GE48 x 10/25GE + 8 x 40/100GE (Uplink ports are unavailable when low latency mode is enabled)
Switching capacity8T/128T8T/128T8T/128T8T/128T
Packet forwarding rate2400Mpps2400Mpps2400Mpps1200Mpps
reliabilityLACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
MoFRR
Supports fine-grained micro-segmentation security isolation (IPv4 and IPv6)
LACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
MoFRR
Supports fine-grained micro-segmentation security isolation (IPv4 and IPv6)
LACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
MoFRR
DPCF
LACP
Hardware BFD (minimum packet interval 3.3ms)
MoFRR
O&MTelemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Telemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Telemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Telemetry
Netstream
ERSPAN Enhancement
Edge intelligence
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Data center characteristics1588v2
MACsec
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
VXLAN over IPv6
VXLAN Mapping
1588v2
MACsec
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
VXLAN over IPv6
VXLAN Mapping
1588v2
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
VXLAN over IPv6
L2/L3 minimum forwarding latency: 320ns~350ns
1588v2
M-LAG
PFC, AI ECN
VXLAN over IPv6
Power consumption147W147W (100% load, 24x25G+4x100G copper ports, ambient temperature, dual AC power supply)
166W (100% load, 24x25G+4x100G port short-range optical modules, room temperature, dual AC power supply)
48x25G+8x100G:
144W (100% load, 24x25G+4x100G copper ports, ambient temperature, dual AC power supply)
163W (100% load, 24x25G+4x100G port short-range optical modules, room temperature, dual AC power supply)
127W
Power supply model600W AC&240V DC
1200W DC
600W AC&240V DC
1200W DC
600W AC&240V DC
1200W DC
400W DC
600W AC&240V DC
1200W DC
Power supply methodAC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC
600W AC & 240V DC Power Supply Module: AC: 100V AC~240V AC, 50/60Hz; DC: 240V DC
1200W DC power supply module: -48V DC to -60V DC; +48V DC
400W DC power supply module: -48V DC to -60V DC; +48V DC
AC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC


7. CE6863 Technical Parameters

modelCE6863E-48S6CQCE6863H-48S6CQ
port48 x 10/25GE+6 x 40/100GE48 x 10/25GE+6 x 40/100GE
Switching capacity4.8Tbps/96Tbps4.8Tbps/96Tbps
Packet forwarding rate2000Mpps2000Mpps
cache42MB42MB
reliabilityDifferential segment
Hardware BFD (minimum packet interval 3.3ms)
LACP
LACP
Hardware BFD (minimum packet interval 3.3ms)
O&MTelemetry
Netstream
sFlow
ERSPAN Enhancement
Telemetry
Netstream
ERSPAN Enhancement
Data center characteristicsVXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC、ECN
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PTP
Power consumption226W226W
Power supply model600W AC&240V DC
1000W -48V DC
1200W HVDC
600W AC&240V DC
1000W -48V DC
1200W HVDC
Power supply methodAC: 90V~290V
DC: -38.4V~-72V
240V HVDC: 190V~290V
380V HVDC: 190V~400V
AC: 90V~290V
DC: -38.4V~-72V
380V HVDC: 190V~400V


8. CE6885-SAN Technical Specifications

modelCE6885-SAN-56F
port48 x 10/25/50GE+8 x 100/200GE
*Use only in centralized storage scenarios
Switching capacity8Tbps
Packet forwarding rate2400Mpps
cache64MB
reliabilityLACP
Hardware BFD (minimum packet interval 3.3ms)
DPFR
O&MTelemetry
Netstream
ERSPAN Enhancement
IFIT
Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility
Data center characteristics1588v2
MACsec
VXLAN routing 和 bridging
BGP-EVPN
M-LAG
PFC, AI ECN
Intelligent lossless networkAI ECN
PFC deadlock prevention
iNOF
NPCC(Network-based Proactive Congestion Control)
ECN Overlay
Power consumption48x25G+8x100G: 147W (100% load, 24x25G+4x100G port copper cable, room temperature, dual AC power supply) 166W (100% load, 24x25G+4x100G port short-range optical module, room temperature, dual AC power supply)
48x50G+8x200G: 177W (100% load, 24 50G copper ports, 4 200G short-distance optical modules, room temperature, dual AC power supply)
Power supply model600 W AC&240 V DC
1200 W DC
Power supply methodAC:90V to 290V;HVDC: 190V~290V
DC: -48V:-38.4V to -72V; +48V DC:+38.4V to+60V